  • Infrared
  • IR
  • LASER
  • UV
  • Butadiene
  • Butane\
  • CO2
  • Ethane\
  • Ethylene
  • Ethylene\
  • HYDROGEN CHLORIDE
  • HYDROGEN FLUORIDE
  • Hydrogen Sulfide
  • Methane
  • NH3
  • Pentane\
  • Propane\
  • Propylene\
  • Ammonia
  • C1-C8
  • C1-C8 flammable gases
  • C2H4
  • Carbon Dioxide
  • CH4
  • CH4 / H2S
  • Ethylene
  • H2S
  • HCl
  • HF
  • Methane (gas mixtures where methane is the main constituent (>70%) and the balance is C2 - C6 hydrocarbons)
  • Methane\
  • Methane\, Ethane\, Propane\, Butane\, Pentane\, Ethylene\, Propylene\, Butadiene
  • ***
  • AEx d IIB + H2 T5 Tamb = -40°C to +60°C [-40°F to 140°F]
  • ATEX Transmitter: II 2 G Ex d op is IIC T5 (Tamb -40°C to +65°C) Gb / II 2 G Ex d op is IIC T6 (Tamb -40°C to +40°C) Gb
  • ATEX Transmitter: II 2 G Ex d op is IIC T5 (Tamb -40°C to +65°C) Gb II 2 G Ex d op is IIC T6 (Tamb -40°C to +40°C) Gb
  • C & D T5 CLASS II DIV 1 GROUPS E\
  • C and D Class II\
  • C and D\
  • C\
  • D and Class 1 Zone 1 AEx d IIB + Hydrogen (Amb -40°C to +65°C)
  • D\
  • Division 1\
  • Dust Ignition proof for Class II\
  • F & G T5 CLASS III DIV 1 Ex d IIB + H2 T5 CLASS I\
  • F and G
  • F and G. Performance per Class no. 6325
  • Groups B\
  • Groups E\
  • IECEx Receiver: Ex d IIC T5 (Tamb -40°C to +65°C) Gb / Ex d IIC T6 (Tamb -40°C to +40°C) Gb
  • IECEx Transmitter: Ex d op is IIC T5 (Tamb =-40°C to +65°C) Gb / Ex d op is IIC T6 (Tamb =-40°C to +40°C) Gb
  • SIL2
  • T5 and Exd IIC T5 (Amb -40°C to +65°C)
  • ZONE 1\
  • ATEX
  • ATEX / IECEX: II 2 GD Exd IIB + H2 T5 Tamb -40°C to +60°C Gb [-40°F to 140°F] Ex tb IIIC T100°C [212°F] Tamb = -40°C to +60°C [-40°F to 140°F] Db IP66/67
  • ATEX & IECEx: Ex II 2 (2) G D Ex db eb ib [ib Gb] IIB+H2 T4 Gb Ex tb IIIC T135°C Db Ta = -55°C to +65°C
  • ATEX Receiver: II 2 G Ex d IIC T5 (Tamb -40°C to +65°C) Gb / II 2 G Ex d IIC T6 (Tamb -40°C to +40°C) Gb
  • ATEX Receiver: II 2 G Ex d IIC T5 (Tamb -40°C to +65°C) Gb II 2 G Ex d IIC T6 (Tamb -40°C to +40°C) Gb
  • ATEX/IECEx :Approved per Ex d e ib [ib Gb] IIB + H2 T4 Gb Ex tb IIIC T135°C Db
  • CSA
  • CSA AND UL: CLASS I DIV 1 GROUPS B\
  • CSA: Class 1 Div 1 groups B\
  • EAC TC RU
  • FM
  • FM:Class I\
  • FM/FMC: Approved per Class I Div 1 Groups B\
  • GOST
  • IECEx
  • IECEx and ATEX: Ex d e ia [ia Ga] IIC T5 Gb Ta
  • III Div 1 Groups E\
  • Independently assessed to IEC61508
  • Inmetro :Ex db eb ib [ib Gb] IIB + H2 T4 Gb Ex tb IIIC T135°C Db X
  • Inmetro: Approved per Ex d e ib [ib Gb] IIB+H2 T4 Gb
  • INMETRO: Ex d IIB + H2 T5 Gb Extb IIIC T100°C [212°F] Db IP66/67 Tamb: -40°C to +60°C [-40°F to 140°F]
  • TR CU/EAC
  • TR CU/EAC: 1Ex d e ib [ib Gb] IIB + H2 T4 Gb X Ex tb IIIC T135°C Db X
  • UL
  • UL: Class 1 Groups B\
  • < 1 second
  • 2 sec
  • 3 sec
  • 5 sec.
  • less than 3 seconds. (under normal operating conditions)
  • T90 - 3 sec
  • T90 < 3 SECONDS
  • T90 ≤ 3SECONDS
  • T90≤10 sec